NGS Mobile X-Ray Machines
STATIC XRAY
MACHINE
COUNTER BALANCE
XRAY MACHINE
 
 
 
 
STATIC XRAY MACHINE
Model 60s 100s 100R
Radiography Rating 15-60mA stations 35KVP to 100 KVP in 15 Step of 5 KVP each 15-60mA stations 35KVP to 100 KVP in 15 Step of 5 KVP each 15-60mA stations 35KVP to 100 KVP in 15 Step of 5 KVP each
Output 5KW 8KW 8KW
Recrtification Full wave rectified Full wave rectified Full wave rectified
Timer Electronic Solid State in 24 Steps 0.06 to 10 Sec. Electronic Solid State in 24 Steps 0.06 to 10 Sec. Electronic Solid State in 24 Steps 0.06 to 10 Sec.
Digital Display Digital Display of mAs. KV & mA Digital Display of mAs. KV & mA Digital Display of mAs. KV & mA
X-Ray Tube BEL DSA-3/Imported BEL DSA-3/Imported BEL DSA-6/Imported
Power Supply 230 Voltage AC, 15 Amps. 230 Voltage AC, 15 Amps. 230 Voltage AC, 15 Amps.
Requirement 50 Hz, Single phase 50 Hz, Single phase 50 Hz, Single phase
Line Regulation 10% 0.6 max 10% 0.4 max 10% 0.4 max
Protection Electronic over-load protection. Electronic over-load protection. Electronic over-load protection.
Tube Stand Counter Balanced Mobile Can easily transported in elevators/lift because of low height. Counter Balanced Mobile Can easily transported in elevators/lift because of low height. Counter Balanced Mobile Can easily transported in elevators/lift because of low height.
Mobility High Mobility High Mobility High Mobility
 
 
COUNTER BALANCE XRAY MACHINE
Model 60s 100s 100R
Radiography Rating 15-60mA stations 35KVP to 100KVP in 15 Step of 5 KVP each 30-100mA stations 35 KVP to 100 LVP in 15 Steps of 5 KVP each 30-100mA stations 35 KVP to 100 LVP in 15 Steps of 5 KVP each
Output 5KW 8KW 8KW
Rectification Full wave rectified Full wave rectified Full wave rectified
Timer Electronic Solid State in 24 Steps 0.06 to 10 sec. Electronic Solid State in 24 Steps 0.06 to 10 sec. Electronic Solid State in 24 Steps 0.06 to 10 sec.
Digital Display Digital Display of mAs. KV & mA Digital Display of mAs. KV & mA Digital Display of mAs. KV & mA
X-Ray Tube BEL DSA-3/Imported BEL DSA-3/Imported BEL DSA-6/Imported
Power Supply 230 Voltage AC, 15 Amps. 230 Voltage AC, 15 Amps. 230 Voltage AC, 15 Amps.
Requirement 50 Hz, Single Phase 50 Hz, Single Phase 50 Hz, Single Phase
Line Regulation 10% 0.6 max 10% 0.4 max. 10% 0.4 max.
Protection Electronic over-load protection Electronic over-load protection Electronic over-load protection
Tube Stand Spring counterBalanced Mobile Can easily transported in elevators/lift because of low height Spring counterBalanced Mobile Can easily transported in elevators/lift because of low height Spring counterBalanced Mobile Can easily transported in elevators/lift because of low height
Mobility High Mobility High Mobility High Mobility
A-3, New Rajinder Nagar,New Delhi - 110060, India
91-11-28742510/28741437